Series 66
Hi-Build Epoxoline
Generic Type
Polyamide Epoxy
Common Usage
Industry standard for epoxy coatings for over 40 years. Known for its forgiving application characteristics in adverse and varied conditions, and for benchmark performance.
View more product detailsProduct Data Sheets
- English_Series_66_Hi_Build_Epoxoline_pds.pdf
- French_Series_66_Hi_Build_Epoxoline_pds.pdf
- Spanish_Series_66_Hi_Build_Epoxoline_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
-
This product is available in 513 colors.
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Volume Solids
56.0 ± 2.0% (mixed) †
Number of Components
Two: Part A and Part B
Topcoats
Series 27WB, 30, 46H-413, 66, L69, L69F, N69, N69F, V69, V69F, 72, 73, 104, 113, 114, 118, 161, 262, 265, 290, 291, 740, 750, 1026, 1028, 1029, 1070, 1070V, 1071, 1071V, 1072, 1072V, 1074, 1074U, 1075, 1075U, 1077, 1078, 1078V, 1094, 1095, 1096, 1224. Note: A maximum recoat time may apply depending on the topcoat specified. Refer to the applicable topcoat product sheet for information on product specific maximum recoat times.
Theoretical Coverage
898 mil sq ft/gal (22.0 m²/L at 25 microns). See APPLICATION for coverage rates. †
Primers
Steel: Self-priming or Series 1, 20, FC20, 37H, L69, L69F, N69, N69F, V69, V69F, 90G-1K97, 90E-92, 90-97, H90-97, 90-98, 91-H₂O, 94-H₂O, 161, 394, V530
Galvanized Steel and Non-Ferrous Metal: Self-priming
Concrete: Self-priming, Series 27WB, 201, 1254
CMU: Series 130, 1254
Drywall: 151-1051 for dry interior environments
Note: A maximum recoat time may apply depending on the topcoat specified. Refer to the applicable topcoat product sheet for information on product specific maximum recoat times.
Curing Time
Temperature | To Touch | To Handle | To Recoat | Immersion |
---|---|---|---|---|
90°F (32°C) | 1 hours | 5-7 hours | 6-8 hours | 4-5 days |
80°F (27°C) | 1.5 hours | 7-9 hours | 8-10 hours | 6-7 days |
70°F (21°C) | 2 hours | 10-12 hours | 12-14 hours | 7-10 days |
60°F (16°C) | 3 hours | 16-20 hours | 20-24 hours | 10-12 days |
50°F (10°C) | 4 hours | 24-30 hours | 30-36 hours | 14-16 days |
Curing time varies with surface temperature, air movement, humidity and film thickness.
Ventilation: When used as a tank lining or in enclosed areas, provide adequate ventilation during application and cure. Reference guidelines contained in the latest edition of AWWA D 102.
Finish
Satin
Recommended DFT
2.0 to 6.0 mils (50 to 150 microns) per coat.
Note: Number of coats and thickness requirements will vary with substrate, application method and exposure. Contact your Tnemec representative.
Volatile Organic Compounds
Unthinned: 3.02 lbs/gallon (362 grams/litre)
Thinned 5%: 3.20 lbs/gallon (384 grams/litre)
Thinned 10%: 3.37 lbs/gallon (404 grams/litre) †