Series H90-97

Tneme-Zinc

Generic Type

Aromatic Urethane, Zinc-Rich

Common Usage

An advanced technology, two-component, moisture-cured, zinc-rich primer providing extraordinary performance. It's user friendly and rapid curing so chemical- and corrosion-resistant topcoats can be applied the "same-day." Also used for field touch-up of inorganic zinc coating. H90-97 is HAPS compliant for use in-shop.

Special Qualifications

Tneme-Zinc uses a zinc pigment which meets the requirements of ASTM D 520 Type III and contains less than .002% lead. This level qualifies it to be classed as "non-lead" (less than 0.009% lead by weight) as defined in 16 CFR Part 1303 of the Consumer Product Safety Commission regulations. Conforms to SSPC Paint 20, Type II.

View more product details

Colors

  • Reddish-Gray

View Available Colors

View available colors in our Color Tool; you can also select and request color swatches.

HAPS

Unthinned: 0.85 lbs/gal solids
Thinned 15%: 0.85 lbs/gal solids

Volume Solids

63.0 ± 2.0% (mixed)

Recommended DFT

2.5 to 3.5 mils (65 to 90 microns) per coat.

Number of Components

Two: Part A and Part B

Volatile Organic Compounds

Unthinned: 2.83 lbs/gallon (339 grams/litre)
Thinned 15%: 2.83 lbs/gallon (339 grams/litre)

Theoretical Coverage

1,011 mil sq ft/gal (24.8 m²/L at 25 microns). See APPLICATION for coverage rates.

Curing Time

Without 44-710

|Temperature †||To Handle||To Recoat|
|75°F (24°C)||1 hour||4 hours|
|65°F (18°C)||1 1/2 hours||5 hours|
|55°F (13°C)||2 hours||6 hours|
|45°F (7°C)||2 1/2 hours||7 hours|
|35°F (2°C)||3 hours||8 hours|
---† 50% relative humidity. Curing time will vary with surface temperature, humidity and film thickness.
Note: For faster curing, low humidity and low-temperature applications, add No. 44-710 Urethane Accelerator (see separate product data sheet).

Topcoats

Series 1, 6, 27, 46H-413, 66, L69, L69F, N69, N69F, V69, V69F, 73, 104, 113, 114, 115, 135, 161, 394, 1028, 1029
Note: Certain topcoat colors may not provide one-coat hiding depending on method of application. Contact your Tnemec representative. Note: Series H90-97 must be exterior exposed for three days prior to topcoating with Series 1028 or 1029.

Still have questions? Request the information you’re looking for:

Request Info

How to Purchase

Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep