Series 90E-92
Tneme-Zinc
Generic Type
Ethyl Silicate Inorganic Zinc-Rich
Common Usage
Self-curing, primer/finish with tenacious bonding and abrasion resistance qualities. Its galvanic action resists undercutting. Excellent stand alone performance in high temperature or long-term atmospheric exposure. Finish with specialized topcoats to improve aesthetics, increase long-term performance or protect the primer from attack in aggressive exposures.
Special Qualifications
Series 90E-92 Tneme-Zinc uses a zinc pigment which meets the requirements of ASTM D 520 Type III and contains less than .002% lead. This level qualifies it to be classed as "non-lead" (less than 0.009% lead by weight) as defined in 16 CFR Part 1303 of the Consumer Product Safety Commission regulations. Series 90E-92 meets the qualitative and performance requirements of SSPC Paint 20 Type 1-C and SSPC Paint 29 Type 1, Level 2.
View more product detailsProduct Data Sheets
- English_Series_90E_92_Tneme_Zinc_pds.pdf
- French_Series_90E_92_Tneme_Zinc_pds.pdf
- Spanish_Series_90E_92_Tneme_Zinc_pds.pdf
Safety Data Sheets
Email this productContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Colors
- Greenish-Gray
View Available Colors
View available colors in our Color Tool; you can also select and request color swatches.
Theoretical Coverage
1,042 mil sq ft/gal (25.6 m²/L at 25 microns). See APPLICATION for coverage rates.
HAPS
Unthinned: 0.41 lbs/gal solids
Thinned 5% (No. 18 Thinner): 0.41 lbs/gal solids
Thinned 9% (No. 15 Thinner): 0.49 lbs/gal solids
Number of Components
Two: Part A and Part B
Recommended DFT
2.0 to 3.5 mils (50 to 90 microns) per coat.
Volatile Organic Compounds
Unthinned: 3.95 lbs/gallon (473 grams/litre)
Thinned 5% (No. 18 Thinner): 4.15 lbs/gallon (497 grams/litre)
Thinned 9% (No. 15 Thinner): 4.17 lbs/gallon (500 grams/litre)
Volume Solids
65.0 ± 2.0% (mixed) void content method
Curing Time
Temperature | To Handle | To Recoat |
---|---|---|
75°F (24°C) | 1 hour | 16 hours |
0°F (-18°C) | 7 days minimum |
Moisture is required to achieve proper cure. Curing time will vary with temperature and humidity. At relative humidities below 30%, it may be necessary to gently spray the coated surface with water to achieve proper cure and to minimize recoat time. Consult your Tnemec representative for specific recommendations. Ventilation: When used as a tank lining or in enclosed areas, provide adequate ventilation during application and cure. Reference ventilation guidelines contained in the latest edition of AWWA D 102.