Series 972
Aerolon Marine
Generic Type
Hybrid Silicone-Acrylic, Anti-Condensation Coating
Common Usage
An innovative anti-condensation coating specifically designed for harsh marine environments. Ideal for reducing or eliminating condensation on bulkheads, overheads, tanks, pipes, ductwork, and other areas within marine vessels. This unique, water-based formulation contains a hydrophobic resin and particle blend that produces a durable, water-resistant system with excellent adhesion and durability. Part of a corrosion-resistant coating system that reduces condensation and issues associated with corrosion under insulation (CUI). Coating film contains biocides that aid in the prevention of mold and mildew growth.
Special Qualifications
Thermal Conductivity (ASTM C518 at 77°F): 0.049 W/m-°K or 0.3396 BTU-in/ft²-hr-°F.
Approved by NAVSEA for Anti-Sweat under 009-32.
Series 972 complies with the requirements for Bulkhead, Wall, and Ceiling applications in accordance with FTP Code IMO Parts 2 and 5.
View more product detailsContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Primers
Steel: Series 1224 or approved epoxy primer
Aluminum & Non-Ferrous Metals: Self-priming
Note: Contact your Tnemec representative for additional information.
Topcoats
Contact your Tnemec representative for more information.
Volume Solids
72% ± 2% (practical)
Recommended DFT
20 to 50 mils (510 to 1,270 microns) per coat.
Maximum IMO total DFT: 150 mils (3,810 microns)
Note: Thickness recommendations will vary depending on specific project requirements and environmental conditions. Contact your Tnemec representative for more information
Theoretical Coverage
1,155 mil sq ft/gal (28.3 m²/L at 25 microns). See APPLICATION for coverage rates.
Number of Components
One
Volatile Organic Compounds
0.26 lb/gal (31 g/L)
HAPS
0.00 lb/gal solids
Curing Time
Temperature^†^ | To Touch | To Handle | To Recoat^‡^ | To Topcoat |
---|---|---|---|---|
95°F (35°C) | 45 minutes | 8 hours | 9 hours | 12 hours |
75°F (24°C) | 2 hours | 16 hours | 18 hours | 24 hours |
45°F (7°C) | 4 hours | 24 hours | 28 hours | 36 hours |
^†^Based on 50% humidity. ^‡^Recoat times listed are with itself. Note: Curing time varies with surface temperature, air movement, humidity, and film thickness. Application in high-humidity conditions may increase curing time.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep