Series 1430
ProPolymer
Generic Type
Epoxy Vinyl Ester
Common Usage
Series 1430 is an FDA-compliant, mineral flake-filled vinyl ester lining for food grade tanks, vessels and other structures. Applied by spray or roller, it can be used as either a stand-alone lining system or as a topcoat for added protection over trowel applied vinyl ester linings. Replaces ProPolymer 4813S.
Special Qualifications
Complies with the requirements and extractive limitations of US FDA 21 CFR Part 175.300 Resinous and Polymeric Coatings for tanks or other repeated use direct food storage or mixing vessels 5 gallons or greater under conditions of use C-E with all food types. Compliance was based upon raw material supplier documents, and third party analytical and extractive test results (HKGH0204112 and HKGH02410973).
View more product detailsContact your sales reps for quotes, problem solving advice, extensive technical knowledge, pricing, ordering and field support.
Surfacer/Filler/Patcher
Series 215, 217, N218, primer with 211-9111 or fumed silica. Note: Series N218 should be used for filling or patching small areas only. For areas in need of full resurfacing, select one of the other recommended products.
Primers
Self-priming on steel or Series 1402 (for FDA food service), 1407. Note: For services above 180°F (82°C), do not use a primer.
Theoretical Coverage
1,363 mil sq ft/gal (33.4 m²/L at 25 microns). See APPLICATION for coverage rates.
Number of Components
Two: Part A (base) and Part B (catalyst)
Volatile Organic Compounds
EPA Method 24
2.06 lbs/gallon (247 grams/litre)
Finish
Semi-gloss
Curing Time
Temperature | To Recoat | Immersion | Maximum Recoat |
---|---|---|---|
90°F (32°C) | 3 hours | 24 hours | 3 days |
75°F (24°C) | 4 hours | 48 hours | 5 days |
60°F (16°C) | 12 hours | 4 days | 7 days |
Recoat times are typical for coating to be dry-to-touch and ready for the next application. Immersion and certain other services may require longer cure times and/or elevated temperature post cure for optimal performance. Direct food contact service requires post cure; see Application Guide. ASTM D2583 Barcol Hardness check is also recommended, minimum 30. Coating that has exceeded its maximum recoat time should be checked for styrene or acetone sensitivity or uniformly scarified to assure secondary bonding. Consult Tnemec Technical Services and Technical Bulletin 22-119 R1.
Volume Solids
85.0 ± 2.0% (mixed). Series 1430 contains a reactive monomer and some loss will occur during application and cure. Actual solids by volume will vary depending upon temperature and air movement.
Recommended DFT
10.0 to 25.0 mils (250 to 635 microns) per coat.
Still have questions? Request the information you’re looking for:
Request InfoHow to Purchase
Tnemec coatings are sold through a select network of local independent sales representatives who can help you find the best product for your needs. Find a rep
Support Documents
TB_99-18_Maintenance of Polymer Floor Coatings.pdf ProPolymer Flier (FLYPRO)